====== SIPURA SPA 1001 ====== ===== Firmware 3.1.5 ===== ==== Register expiry BUG (?) ==== In version 3.1.5 (and possible earlier versions) the SPA-1001 does not obey the register expires modified by the OpenSER proxy. Example: UAC has default expire=3600 and uses this in its Contact header. The OpenSER proxy returns a smaller interval in the OK reply, for instance expires=1800. The SPA-1001 still uses 3600 as registration interval.